Connection top/bottom - top Details Attached配置
Source / Beamline: Source - I.H.C Vaporizer Option - No Source Chamber Shield Kit - yes IBS Xtensy Source - yes Mass Slit Shield Retrofit - no Gasbox: String #1 - SDS - MKS-P2A -- 10scccm String #2 - SDS - Unit-1662 -- 10scccm String #3 - HP - Unit-1201A -- 10sccm String #4 - HP - Unit-1201A -- 10sccm External Inert Gas Feed and Purge Endstation: Implant Disc - 13 Site, Silicon Coated New Infranor Amplifier Xtra Puls - yes Spin Amp Kollmorgen - Servo Star S670 2 dimensional Profiler - yes Control System: Computer - 147MHz Main & ES CPU Software Ver - 6.24 Backup Disc - Floppy Drive Cleanroom Monitor - TFT Remote Monitor - TFT Light Tower - Yes High Vac Pumps: Source Turbo - Pfeiffer 1500 (Pump maybe not included, depends on decon posibility) Beamline Turbo - Pfeiffer 1200 (Pump maybe not included, depends on decon posibility) Manifold Turbo - Pfeiffer Endstation Cryo P1 - CTI 250F P/N: 8039113 (Pump maybe not included, depends on decon posibility) Endstation Cryo P2 - CTI 250F P/N: 8039113 (Pump maybe not included, depends on decon posibility) Endstation Cryo P3 - CTI 250F P/N: 8039113 (Pump maybe not included, depends on decon posibility) Endstation Cryo P5 - CTI 250F P/N: 8039113 (Pump maybe not included, depends on decon posibility) Dry Roughing Pumps: Terminal Differential Seal - Membran Endstation Differential Pump - Membran or Scroll Pump Remote Facility Rack: Cryo Comp 1 - 9600LV Cryo Comp 2 - 9600LV 50 Hz Frequency Converter - yes Spare Assys: Source - I.H.C Extency SourceOEM 代工型號說明
The VIISion 200 is a high current ion implantation system that autotunes and implants high doses with high beam currents for improved throughput. The design of the ion optics allows low energy implants in drift mode. When implanting with high currents, a plasma flood gun system is used to prevent wafer charging problems. The beam line design incorporates a number of significant features to enhance the generation and transport of ion beams with high efficiencies and minimal heavy metals and particle production. These include a dual filament ion source, a constant current extraction system with variable z axis and suppression voltage, a very high resolving power high acceptance mass analysis system, a rotating mass defining slit, a variable gap acceleration system and a full faraday in front of the wafer.文檔
類別
High Current
上次驗證: 17 天前
關鍵商品詳情
條件:
Used
作業狀態:
未知
產品編號:
153194
晶圓尺寸:
8"/200mm
年份:
1997
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
類似上架商品
查看全部APPLIED MATERIALS (AMAT) / VARIAN
VIISion 200
類別
High Current
上次驗證: 17 天前
關鍵商品詳情
條件:
Used
作業狀態:
未知
產品編號:
153194
晶圓尺寸:
8"/200mm
年份:
1997
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available