描述
The Keysight N4433A Microwave electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full three- or four-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable to mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest. ECal modules are transfer standards capable of transferring the factory calibration accuracy to your network analyzer. The Keysight PNA and ENA series of network analyzers controls the N4433A module directly through a USB interface. PNA Series network analyzers require firmware revision 2.5 or higher. HIGHLIGHTS • 300 kHz to 20 GHz frequency range • Standard 3.5 mm (f) connectors • Fast full 3- or 4-port calibration with a single connection • NIST traceable accurate calibrations • Reduced connector wear • USB interface for direct control with PNA and ENA series of network analyzers • Reliable solid-state switching • Mixed 3.5 mm male/female connectors option available
配置
Opt010
OEM 代工型號說明
N4433A Electronic Calibration Module (ECal), 300 kHz to 20 GHz, 3.5 mm, 4-port. The Keysight N4433A Microwave electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full three- or four-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable to mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
文檔

無文檔

類別
Electronic Test

上次驗證: 超過30天前

關鍵商品詳情

條件:

Used


作業狀態:

Deinstalled / Uncrated


產品編號:

64597


晶圓尺寸:

未知


年份:

2014


Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available

KEYSIGHT / AGILENT / HEWLETT-PACKARD (HP)

N4433A

verified-listing-icon
已驗證
類別
Electronic Test
上次驗證: 超過30天前
listing-photo-698c95031a504f9b981500adb08f4bb4-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/47868/698c95031a504f9b981500adb08f4bb4/8f16cb60ab95406d9c8853e2ac753e3f_73fe39dcad904222996c36d64d3f29bb1201a_mw.jpeg
listing-photo-698c95031a504f9b981500adb08f4bb4-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/47868/698c95031a504f9b981500adb08f4bb4/4e0721681b0f4081840f5d24797e8743_41c29df20aaa4e359234d56a236fdbd51201a_mw.jpeg
listing-photo-698c95031a504f9b981500adb08f4bb4-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/47868/698c95031a504f9b981500adb08f4bb4/f33ca557a33d4007a5de00e2456c9ccb_170e682c3a404de3b7890570153039711201a_mw.jpeg
listing-photo-698c95031a504f9b981500adb08f4bb4-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/47868/698c95031a504f9b981500adb08f4bb4/2c3861fcb2d04471a843f60e49c06388_69a44e589de842bcb5eaaf39c8674102_mw.jpeg
listing-photo-698c95031a504f9b981500adb08f4bb4-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/47868/698c95031a504f9b981500adb08f4bb4/bcc1bb6c6c854f25ab3915fea3b7f968_7c0eaaa1a5c7441c80b6cb0b282096471201a_mw.jpeg
關鍵商品詳情

條件:

Used


作業狀態:

Deinstalled / Uncrated


產品編號:

64597


晶圓尺寸:

未知


年份:

2014


Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
描述
The Keysight N4433A Microwave electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full three- or four-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable to mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest. ECal modules are transfer standards capable of transferring the factory calibration accuracy to your network analyzer. The Keysight PNA and ENA series of network analyzers controls the N4433A module directly through a USB interface. PNA Series network analyzers require firmware revision 2.5 or higher. HIGHLIGHTS • 300 kHz to 20 GHz frequency range • Standard 3.5 mm (f) connectors • Fast full 3- or 4-port calibration with a single connection • NIST traceable accurate calibrations • Reduced connector wear • USB interface for direct control with PNA and ENA series of network analyzers • Reliable solid-state switching • Mixed 3.5 mm male/female connectors option available
配置
Opt010
OEM 代工型號說明
N4433A Electronic Calibration Module (ECal), 300 kHz to 20 GHz, 3.5 mm, 4-port. The Keysight N4433A Microwave electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full three- or four-port calibration takes less than half the time and number of connections using ECal versus mechanical cal kits. Furthermore, the accuracy of the calibration is comparable to mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
文檔

無文檔