跳到主要內容
Moov logo

Moov Icon
CANON APT-5800
    描述
    無描述
    配置
    Process Atomosphere pressure CVD (BPSG) Wafer Size 200MM Wafer Shape Notch Wafer Cassette 8" Plastic Miraial SMIF Interface NO <1> Enclosure 1. Door 2.Load window 3.Clean unit Spec. ULPA Filter (0.1μm) <2> Wafer Handring 1. Casette stage Stage# Casette x2, Dummy casette x1 Wafer size 5-8 inch combination 2. Cooling station 3. Wafer handring robot Function Back surface adsorption Alignment of orientation flat Model GENMARK GENCOBOT Ⅳ 4. Elevator Wafre guide size 8 inch 5. Index table Susceptor Material: SiC Guide ring Material: Quarts Heat shield Material: SUS Susceptor support Material: SUS Rotation table <3> Process gas supply 1. AFC box MFC Aera FC-782/781 Filter Pall GLF6101/GLFPF8101 Regulator Tescom 44-3200 Air operated valve Fujikin MEGA-ONE 2. Bubbling unit 3. Heat pipe <4> Other supply 1. Air supply Aux N2, Vac. Gen N2 2. Colling water <5> Process reaction 1. Disversion head (D/H) 2. Reactor heater <6> Exhaust 1. Enclosure exhaust damper 2. Reactor exhaust damper 3. Reactor exhaust pipe unit 4. Manometer unit General exhaust Process exhaust 5. Drain tank system Tank capacity 10 little 6. Ozone treatment machine Method Catalyst system 7. Rotary brush Method Brush up + Vacuum <7> Sub system 1. Ozonizer Model Sumitomo Seimitsu SGN-04CUA 2. Liquid source supply system Spec. TEOS, TMOP, TEB 3. Chillor unit Model NESLAB CFT-25 <8> Conrol & Electric equipment 1. User interface Computor, Display, Key board 2. System controller VME controller Robot controller Rotation controller Temperature controller 3. Maintenance PC IBM compatible 4. Electric equipment <9> Safety 1. Gas detection unit Model Shincosmos Electric V880 2. UPS Model CLARY UPS1-1.25k-1G 3. Interlock 4. EMO x4
    OEM 代工型號說明
    未提供
    文檔

    無文檔

    CANON

    APT-5800

    verified-listing-icon

    已驗證

    類別

    CVD
    上次驗證: 超過60天前
    關鍵商品詳情

    條件:

    Used


    作業狀態:

    未知


    產品編號:

    18315


    晶圓尺寸:

    8"/200mm


    年份:

    未知

    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    類似上架商品
    查看全部
    CANON APT-5800
    CANONAPT-5800CVD
    年份: 1996條件: 二手
    上次驗證超過60天前

    CANON

    APT-5800

    verified-listing-icon

    已驗證

    類別

    CVD
    上次驗證: 超過60天前
    listing-photo-KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/0w1AOC-jGpzkjVqwmaqMBQHV6fzSFgHuv0bCW3MPMJY/KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA/pY85fOtZnMDUyAm9Rcu5z1A5lQpM928-nf1hn5kfu88_20181005_063204_f
    listing-photo-KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/0w1AOC-jGpzkjVqwmaqMBQHV6fzSFgHuv0bCW3MPMJY/KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA/dqZJvQMy2rLZi4AiSiqUdQCUXijpwt5XyvAy6hSfbIg_20181005_063204_f
    listing-photo-KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/0w1AOC-jGpzkjVqwmaqMBQHV6fzSFgHuv0bCW3MPMJY/KjoK9vIQjmw6eg9japcAhklerTLfKrSZXCjfXetQyVA/obmIb0HDtCwYBXVvJZzFkhcfJuELoTdMGa5SW7k3UiM_20181005_063204_f
    關鍵商品詳情

    條件:

    Used


    作業狀態:

    未知


    產品編號:

    18315


    晶圓尺寸:

    8"/200mm


    年份:

    未知


    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    描述
    無描述
    配置
    Process Atomosphere pressure CVD (BPSG) Wafer Size 200MM Wafer Shape Notch Wafer Cassette 8" Plastic Miraial SMIF Interface NO <1> Enclosure 1. Door 2.Load window 3.Clean unit Spec. ULPA Filter (0.1μm) <2> Wafer Handring 1. Casette stage Stage# Casette x2, Dummy casette x1 Wafer size 5-8 inch combination 2. Cooling station 3. Wafer handring robot Function Back surface adsorption Alignment of orientation flat Model GENMARK GENCOBOT Ⅳ 4. Elevator Wafre guide size 8 inch 5. Index table Susceptor Material: SiC Guide ring Material: Quarts Heat shield Material: SUS Susceptor support Material: SUS Rotation table <3> Process gas supply 1. AFC box MFC Aera FC-782/781 Filter Pall GLF6101/GLFPF8101 Regulator Tescom 44-3200 Air operated valve Fujikin MEGA-ONE 2. Bubbling unit 3. Heat pipe <4> Other supply 1. Air supply Aux N2, Vac. Gen N2 2. Colling water <5> Process reaction 1. Disversion head (D/H) 2. Reactor heater <6> Exhaust 1. Enclosure exhaust damper 2. Reactor exhaust damper 3. Reactor exhaust pipe unit 4. Manometer unit General exhaust Process exhaust 5. Drain tank system Tank capacity 10 little 6. Ozone treatment machine Method Catalyst system 7. Rotary brush Method Brush up + Vacuum <7> Sub system 1. Ozonizer Model Sumitomo Seimitsu SGN-04CUA 2. Liquid source supply system Spec. TEOS, TMOP, TEB 3. Chillor unit Model NESLAB CFT-25 <8> Conrol & Electric equipment 1. User interface Computor, Display, Key board 2. System controller VME controller Robot controller Rotation controller Temperature controller 3. Maintenance PC IBM compatible 4. Electric equipment <9> Safety 1. Gas detection unit Model Shincosmos Electric V880 2. UPS Model CLARY UPS1-1.25k-1G 3. Interlock 4. EMO x4
    OEM 代工型號說明
    未提供
    文檔

    無文檔

    類似上架商品
    查看全部
    CANON APT-5800
    CANON
    APT-5800
    CVD年份: 1996條件: 二手上次驗證: 超過60天前